On this page:

On this site:

FC7008 Frequency counter

M51-front.jpg
Having read about this design in the ELV magazine in 1999, I liked it a lot so I ordered the kit and built it. Though this was my first experience with SMD components, all went well and the counter worked fine, at first. Trouble later on could be fixed. In order to calibrate the instrument I had to come up with some tricks. Calibration succeeded and I was quite satisfied with this counter.
This frequency counter is microcontroller-driven, like many of the frequency counters you find today. Using a microcontroller gives a lot of flexibility for different operating modes, and it gives you the opportunity to calculate frequency from time and vice versa. This results in much more precise readings with a moderate gate time. And of course, a microcontroller-based design uses less components. A TTL-based frequency counter I built in 1980 had number of boards and the controller board that generated the gating signals and selected between period/time and frequency, was complex and inflexible.

The FC7008 has an 8-digit multiplexed display. It can measure up to 80 MHz on its standard input. There is also a divide-by-100 prescaler that goes up to 1.3 GHz. Push-button switches are used to select operating mode and gate time. Inside is a 25 MHz "OCXO" (oven-controlled crystal oscillator). This should give the device a precision of a few ppm. That is, if you have facilities to calibrate the device... There is also a cheaper version, the FC7007, with only seven digits, no OCXO and no prescaler.

Now of course, to build a kit is much less impressive than to design it yourself. But it was a nice experience, yielding results quickly. The kit is well designed and everything was complete. This also meant things went fast. The assembly was finished in a few nights.

There were a lot of SMDs in the circuit. For me this was the first experience with SMD components as an amateur. But it went well. I used a very thin point (0.8 mm) for my soldering iron, and thin solder wire. Positioning a component with a pair of tweezers, you can make one of the ends stick to one of the solder pads. then solder the other end and resolder the first end using just enough solder. This procedure is much slower than what I you can do with normal wired components, but it works.

Chassis seen from behind

Chassis taken out of case, seen from behind.

The counter did not work immediately. I had forgotten some of the connections between the two circuit boards. A washer under one of the screws that fix the front board to the main board caused a short circuit because it touched a trace on the front circuit board. This could easily be corrected by shifting the washer a bit. I would consider this a design flaw, the hole should not have been so close to the trace.

top

Fixing oscillator trouble

This counter contains an oven-controlled reference oscillator (OCXO). This is actually a separate kit that is included with the FC 7008 kit. I built it and tested it. Although the output voltage was less than specified, it was within the range TTL circuits need so I did not give this much consideration.

After two months, the counter did not work any more. It was able to count events but not frequency or period. The "measuring" LED was almost constantly on indicating that the measurement cycle was somehow disturbed. I opened up the cabinet and started searching signals with a scope. After analysing the circuits I came to the conclusion that the input circuit wasn't triggered properly. Then I found out that the reference signal wasn't there. The OCXO didn't work.

I made a quick and dirty fix by connecting the output of the 16 MHz clock oscillator to the "external reference" input. Now at startup the counter said "ref ext - 16 MHz", which is quite correct from its point of view, and measured frequency again. Of course, the clock was not calibrated, but for the moment that was not an issue.

I opened the oscillator and poked my scope's probes in it (re-opening wasn't easy, the guys at ELV have not designed this crystal oven to be serviced). It seemed that the Collpits oscillator was dead. Touching one of the crystal leads started it, however. Apparently the oscillator was marginal. I played a bit with the capacitors in the divider in the crystal circuit and got it back to work again. Apparently, the capacitors did not fit the crystal very well.

As I said, something was wrong with the output voltage. I checked the output buffer and found out that the signal went all up against the positive supply rail, but not to ground. Apparently the output transistor was not biased properly. After some quick calculations I decided that the output circuit's bias was very sensitive to component variations. I changed the bias and got a satisfactory 4 Vtt output.

top

BBC for calibration

Now I had repaired it, I wondered what use the crystal oven was if I couldn't calibrate it.

I remembered that the carrier of some radio stations is kept very precise by coupling it to an atomic clock. In 1973, Radio Bulletin described a calibration procedure that used the Droitwich LW station as a reference, which was broadcasting on 200 kHz at the time. They tapped a 100 kHz signal divided from the oscillator to be calibrated, and coupled it loosely to the ferrite antenne of a portable radio tuned to Droitwich on 200 kHz. The interference of the two signals caused a beat frequency equal to the frequency difference. They tuned the oscillator so that the beat frequency was as low as possible. I once used this procedure and it worked.

Looking for "Droitwich" and "frequency reference", I found a page "Using BBC transmissions as a frequency reference" on the BBC web site. Fortunately, I made a printout of it, because the page seems to have disappeared since. It told me that Droitwich was on 198 kHz now, which is a bit of an awkward frequency if you want to use the Radio Bulletin interference method. Just to use the signal from a radio station as the input for the frequency counter didn't seem practical because the signal is too weak to use as an input for the counter and because noise will disturb your measurements. You'd have to build a small-bandwidth tuned RF amplifier to do this, maybe a PLL to replicate the reference signal without noise. As I found later, a TRF receiver with feedback is fine for this. As BBC indicated, the short-term accuracy of a received radio station frequency is not so good because of phase differences due to atmospheric conditions. I wouldn't get eight-digit accuracy.

The good news was that BBC has other precision signals. On their TV broadcasts they keep the PAL color subcarrier signal within 1 Hz of the specified value of 4.43361875 MHz. This is a signal you can easily recover from an analogue color TV. In a color TV there is a local crystal oscillator that is kept in phase with the color reference signal from the broadcast station. So I thought, because the local oscillator is kept in phase with the reference signal, it must almost have the same +/-1 Hz precision. Now this may not be completely true. The TV broadcast signal may suffer quite large phase shifts that remain invisible because the color subcarrier and the reference signal will suffer the same amount of phase shift. As long as the local oscillator in your TV can follow the phase shifts, the image is good. But as long as the phase shift is constant, the frequency is too. Maybe someone someday will provide me with a thorough error analysis so we will know exactly what the precision of the received signal is.

I did not give this much thought and assumed the signal path from London to my house was good enough to get away with it. So I decided to calibrate the counter using the color reference signal tapped from a portable TV when tuned in to BBC. Finding the 4.43 MHz crystal in the TV was easy. Although all the circuitry for color demodulation was around a single IC, it was easy to see what the output of the oscillator was by analysing the circuitry around the crystal. I connected a 10:1 probe to it that went to the input of the counter.

Calibration

Calibration set-up as in 2000.

Now don't try this at home if you don't know what you are doing. You may severely damage your TV set and your health, too, if you don't know what parts of the inside have dangerous voltages.

The OCXO has two adjustment controls: one coarse, this is a trimming capacitor on the inside, and one fine, this is an external control voltage for a varicap diode parallel to the trimming cap. There is a multiturn pot on the main board to set the control voltage. The fine adjustment has a range of less than 100 Hz so you can't afford not to set the trimming cap first. Unfortunately, you have to take the OCXO apart to reach the trimming cap, you cannot set it in-circuit but have to do that on your bench.

First, I added a trimmer capacitor to the clock oscillator to be able to calibrate it. I trimmed it to get a reading of 4.433619 MHz.

Then I used the now calibrated counter to adjust the OCXO to 25.000 000 MHz on my workbench. It was now as precise as the clock oscillator was.

After setting the trimming cap, I sealed the oscillator and soldered it in place. I let the counter and OCXO warm up for half an hour. Then I connected the counter to the TV and adjusted the fine control to get a reading of 4.4336188 MHz. The counter had to be set to 10 s gate time to get a reading with a resolution of 0.1 Hz like this. End of calibration, no expensive reference equipment used! I made the photograph at the top of this page to prove all this.

Switching my TV between channels, I noticed that most broadcast stations were also quite precise. The stations that were off more than 10 Hz were commercial TV stations. Is this because a precision subcarrier does not pay, or is that because they use broadcast satellites, having the signal suffer from relativistic effects that change the flow of time when the signals are travelling up and down the satellite?

Still later, when I was aligning the UM58 regenerative receiver, I accidentally found another way to align a frequency counter to broadcast transmissions. Normally, the signal from a broadcast station is too weak to be used as an input to a frequency counter. But when you set the feedback control of a regenerative receiver so that it just oscillates, you can use the receiver as a powerful amplifier and filter. When the receiver is oscillating, you hear a note. This is the beat frequency, the difference between the broadcast signal and the receiver's oscillating detector stage. As you tune in to the station, the tone will become lower as you approach the real frequency of the broadcast station. Suddenly, the tone disappears when the detector locks in with the station. I noted that in this stage, the readout of a frequency counter hooked up to the detector output is very stable. So you are looking at the broadcast station's frequency, the signal being amplified by the oscillating detector stage, locked to the broadcast station.

After all this trouble, I mean fun, the counter has proved to be a useful and easy to use instrument for many years.

top

New faults

With the years, gradually it needed more and more time to start up. It was again the OCXO that only started working after a long warm-up time. In 2025, another problem occurred. I was using the counter to check the frequency while aligning the KY585 radio. Suddenly a cloud of smoke rose, with a nasty smell of burnt epoxy. The counter stopped working.

I opened it up and saw that the mains decoupling capacitor had failed and the fuse was blown. This is a type of mixed-dielectric capacitor intended for this purpose, but notorious for running hot and eventually failing. I replaced it, inserted a new fuse and the FC7008 was working again. But the OCXO still needed too much time to start. So I rewired the counter again to use the internal clock oscillator as reference.

Burnt filter capacitor

The mains filter capacitor that ejected its smoke.

I will fix the OCXO later.
top

Recalibration

Calibration will be another challenge. Twenty-five years later, analogue TV broadcasts are a thing of the past. No more color subcarrier locked to an atomic clock. Maybe GPS. But how to use that? I'll have to find out.

Copyright © 2000-2026 by Onno's E-page         published 2001-03-11, last updated 2026-04-17